www.schneider-electric.us
TeSys(R) GV2 and GV3 Manual Starter and Protector
Refer to Catalog 2520CT0001
www..com
The GV family of products are 3-pole, horsepower rated, UL 508 listed, manual starters. They include a manual disconnect, class 10 ambient-compensated thermal overload relay, and an instantaneous magnetic trip mechanism in one compact unit. Any GV manual starter can be used alone for local manual control of a motor with individual full-load currents up to 220 amps. The GV family of products may also be used in group motor installations in accordance with National Electric Code article 430-53. Group motor installations give you greater panel density for smaller size and require fewer parts and less wiring necessary for installation when compared to conventional panel designs. The GV2P and GV3P products also have an additional UL 508 type E rating as a stand alone self-protected manual combination starter. The UL 508 type E rating requires the addition of line side insulating barrier GV2GH7 for the GV2P or part number GV3G66 for the GV3P. The GV2P and the GV3P self-protected manual combination starter may also be combined with specific size contactors from the LC1D product family for a UL 508 Type F combination starter construction. These products have UL-listed short circuit current rating from 10-100 KA depending on application size and voltage. See www.us.telemecanique.com for more information.
How to Order
GV2ME
To order the basic motor starter, select the model number (GV2ME**, GV2P**, or GV3P**) with the appropriate thermal setting from the table below. The thermal trip range and setting should be determined from the motor nameplate fullload current. Table 18.124:
Maximum Horsepower Ratings Thermal Setting (A) 1O 3O Group Motor Applications GV2/3M push button GV2/3P rotary handle $ Price 212. 212. 212. 233. 233. 233. 233. 233. 233. 233. 278. 278. 278. 278. 278. 404. 404. 404. 404. 504. 504. 504.
GV2P21 with GV2GH7 installed
115 V 230 V 200 V 230 V 460 V 575 V Max. Fuse or Catalog Catalog $ Price hp hp hp hp hp hp Circuit Breaker Number Number 0.11-0.16 -- -- -- -- -- -- 1200 A GV2ME01a 159. GV2P01 0.16-0.25 -- -- -- -- -- -- 1200 A GV2ME02a 159. GV2P02 0.25-0.40 -- -- -- -- -- -- 1200 A GV2ME03a 159. GV2P03 0.40-0.63 -- -- -- -- -- -- 1200 A GV2ME04a 180. GV2P04 0.63-1 -- -- -- -- 0.5 0.5 1200 A GV2ME05a 180. GV2P05 1-1.6 -- 0.1 -- -- 0.75 1 1200 A GV2ME06a 180. GV2P06 1.6-2.5 -- 0.667 0.5 1 1.5 1200 A GV2ME07a 180. GV2P07 0.5 2.5-4 1/8 0.333 0.75 1 2 3 1200 A GV2ME08a 180. GV2P08 4-6.3 1/4 0.5 1.5 1.5 3 5 1200 A GV2ME10a 180. GV2P10 6-10 0.5 1.5 2 3 5 7.5 1200 A GV2ME14a 180. GV2P14 9-14 0.75 2 3 3 10 10 1200 A GV2ME16a 224. GV2P16 13-18 1 3 5 5 10 15 1200 A GV2ME20a 224. GV2P20 17-23 1.5 3 5 7.5 15 20 1200 A GV2ME21a 224. GV2P21 20-25 2 3 5 7.5 15 20 1200 A GV2ME22a 224. GV2P22 24-32 2 5 10 10 20 30 1200 A GV2ME32 224. GV2P32 9-13 0.5 1.5 3 3 7.5 10 -- -- GV3P13 New! 12-18 0.75 2 5 5 7.5 10 -- -- GV3P18 17-25 1.5 3 7.5 7.5 15 20 -- -- GV3P25 23-32 2 3 10 7.5 20 25 -- -- GV3P32 30-40 3 5 10 10 25 30 -- -- GV3P40 37-50 3 7.5 15 10 30 40 -- -- GV3P50 48-65 3 10 20 15 40 50 -- -- GV3P65 a For spring terminals add 3 to the catalog number, for example, GV2ME013. GV2ME32 is not available with spring terminals.
Table 18.125:
GV3P
Thermal Setting (A) 1O 115 V hp -- -- -- -- -- -- -- -- 230 V hp -- -- -- -- -- -- -- -- 200 V hp -- -- -- -- -- -- -- -- 230 V hp 5 7.5 10 15 30 30 50 75 Maximum Horsepower Ratings 3O 460 V hp 10 15 30 30 60 75 100 150 575 V hp 15 20 30 40 75 100 150 200 Catalog Number GV7RE20 GV7RE25 GV7RE40 GV7RE50 GV7RE80 GV7RE100 GV7RE150 GV7RE220 Toggle Operator Standard Interrupt $ Price 417. 417. 417. 417. 417. 456. 502. 502. High Interrupt Catalog Number GV7RS20 GV7RS25 GV7RS40 GV7RS50 GV7RS80 GV7RS100 GV7RS150 GV7RS220 $ Price 813. 813. 813. 813. 813. 891. 978. 978.
12-20 15-25 25-40 30-50 48-80 60-100 90-150 132-220
GV7RE20
Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-36 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-34 to 18-35 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-52 to 18-55
E164864 CCN NLRV LR81630 Class 3211 05
(c) 2009 Schneider Electric All Rights Reserved
I11
Discount Schedule
18-33
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
18
IEC CONTACTORS AND STARTERS
Starters Accessories
TeSys(R) GV2 and GV3 Manual Starters and Protectors
Refer to Catalog 2502CT0001 Table 18.126: Voltage Trips
Only one trip or fault signaling contact can be installed per GV2/GV3 device. Characteristics Voltage Frequency Catalog Numbera $ Price 50 Hz GVA*025 24 V 60 Hz GVA*026 50 Hz GVA*055 48 V 60 Hz GVA*056 100-110 V 50/60 Hz GVA*107 50 Hz GVA*115 110-115 V 60 Hz GVA*116 120-127 V 50 Hz GVA*125 127 V 60 Hz GVA*115 Undervoltage or 200 V 50 Hz GVA*207 Voltage trips Shunt trip 200-220 V 60 Hz GVA*207 81.00 GV2 & GV3P (external mount, 50 Hz GVA*225 1 block right side only) 220-240 V 60 Hz GVA*226 50 Hz GVA*385 380-400 V 60 Hz GVA*386 415-440 V 50 Hz GVA*415 415 V 60 Hz GVA*416 440 V 60 Hz GVA*385 480 V 60 Hz GVA*415 500 V 50 Hz GVA*505 600 V 60 Hz a To order an under voltage trip: replace the bullet (*) with a U, example: GVAU025. To order a shunt trip: replace the bullet (*) with an S, example: GVAS025. Description
www..com www.schneider-electric.us
GVAU116
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
18
IEC CONTACTORS AND STARTERS GVAE11 GVAD0101 GVAN11
Table 18.127: Auxiliary Contact Blocks
Description Mounting Location Frontbg Left Hand Side Fault signaling contact + instantaneous auxiliary contact GV2 + GV3P Max. No. of Blocks 1 2 Contact Type N.O. or N.C.c N.O. + N.C. N.O. + N.O. N.O. + N.C. N.O. + N.O. N.O. (fault) + N.O. N.O. (fault) + N.C. N.C. (fault) + N.O. N.C. (fault) + N.C. Sold in lots of 1 10 1 1 1 1 1 1 1 Catalog Number GVAE1 GVAE11e GVAE20e GVAN11e GVAN20e GVAD1010 GVAD1001 GVAD0110 GVAD0101 GVAM11 $ Price 21.80 35.70 35.70 35.70 35.70 54.00 54.00 54.00 54.00 35.70
Instantaneous auxiliary contacts GV2 + GV3P
Left Hand Sided
1
b c d e f g
Short circuit signaling contact Left Hand Side 1 SPDT 1 GV2 + GV3P Mounting of a GVAE contact block or a GV2AK00 visible isolation block on GV2P. Choice of N.C. or N.O. contact operation, depending on which way the reversible block is mounted. The GVAD is always mounted next to the starter. For spring terminals add 3 to the catalog number. Example: GVAE113 One trip or one fault signaling can be fitted per GV3. Cannot be used with GV2GH7 insulator.
Table 18.128: Voltage Trips-Technical Data (GV2AU, GV2AS)
Rated Voltage-660 Vac Model Inrush Sealed Pick-Up Voltage GVAU 12 VA / 8 W 3.5 VA / 1.1 W 0.8 to 1.1 GVAS 14 VA / 10.5 W 5 VA / 1.6 W 0.7 to 1.1 From the loss of voltage at the trip terminals to the opening of the starter contacts. Drop-Out Voltage 0.35 to 0.7 0.2 to 0.75 Operating Timeh 10 to 15 ms 10 to 15 ms
h
Table 18.129: GV3P Accessories New!
Description Set of 3-pole 115 A busbars (tap-offs: 2, pitch: 64 mm) Set of 3-pole 115 A busbars (tap-offs: 3, pitch: 64 mm) Cover "Larger Spacing" UL 508 type E (Only one cover required on supply side) IP 20 cover (Two covers required per starter) Padlocking device For use with up to 4 padlocks (not supplied) O 6 mm shank maximum For GV3P GV3P** GV3P** GV3P** GV3P** GV3P** GV3P*** Catalog Number GV3G264 GV3G364 GV3G66 LAD96570 GV2V03 $ Price 25.00 45.00 18.00 12.00 15.00
18-34
CP10
I11
Discount Schedule
(c) 2009 Schneider Electric All Rights Reserved
Starters Accessories * * * * * *
TeSys(R) Manual Starters and Protectors LS1 Fuseholders
Refer to Catalog 2502CT0001
45 mm wide (same dimensions as GV2ME) Available with screw clamp and spring type terminals Mounts directly to LC1D09-D32 contactors (with use of GV2AF3 or GV2AF4) Meets application needs for fusible starter Uses GV2AE instantaneous contact blocks to open control circuits DIN rail mounted
www..com www.schneider-electric.us
Table 18.133:
IN mm Spring terminals, 3-pole CC, KTK-R 0.41 x 1.5 10.3 x 38 Screw clamp terminals, 3-pole CC, KTK-R 0.41 x 1.5 10.3 x 38 Spring terminals, 3-pole aM, gG 0.39 x 1.5 10 x 38 Screw clamp terminals, 3-pole aM, gG 0.39 x 1.5 10 x 38 Auxiliary main pole adder aM, gG 0.39 x 1.5 10 x 38 a Can be mounted on left-hand or right-hand side of the 3-pole LS1D32 block. Description Fuse Type Dimensions Use In US Markets US Markets European Markets European Markets European Markets Catalog Number LS1D303 LS1D30 LS1D323 LS1D32 LA8D324a $ Price 86. 86. 101. 86. 65.
Table 18.134: Specifications
Type Max. voltage Max. current LS1D30, LS1D303 LS1D32, LS1D323, LS1DT32 600 V 3 Phase 30 A IEC 60947-1, 60947-2, 60947-4-1, EN60204, BS4841, UL 508, CSA 222.2 No. 14, NFC 63-650, 63-120, 79-130, VDE 0113, 0660 UL, CSA BV "TH" "TH" oF -58 to 158 (-50 to +70o C) Max. 2-#8 2-#8 AWG (2-6 mm2) 2-#10 AWG (2-4 mm2) 0.5 J 15 in-lb (1.7 N*m) No AWG (2-6 mm2) Min. 2-#16 (2-1 2-#14 (2-1 mm2) 2-#16 AWB (2-1 mm2) mm2)
90
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
18
IEC CONTACTORS AND STARTERS
Conforming to standards
LS1D30
Product approvals Protective treatment Ambient air temperature --operation Wiring Number of conductors and cross sectional area (c.s.a.) Solid cable Flexible cable without cable end Flexible cable with cable end Resistance to mechanical impact conforming to IEC 60947-1 7-1-6 Tightening torque Sensitivity to phase failure
Table 18.135: Specifications
Operating Positions:
30
30
File E164864 CNN NLRV
90
File LR81630 Class 3211 05 Shock resistance--30 g (conforming to IEC 600 68-2-27) Vibration resistance--5 g (5 to 150 Hz) (IEC 600 68-2-26) Ambient temperature: -40 to 176oF (-40 to +80oC) for storage -4 to 140oF (-20 to +60oC) open operation -4 to 104oF (-20 to +40oC) enclosed operation Maximum operating life--25 operations per hour Operating current of magnetic trip is approximately 13 times maximum thermal trip (non-adjustable setting)
Rated voltage--600 V Rated thermal current--25 A (GV2), 63 A (GV3) Mechanical life: GV2:
100,000 operations
18-36
I11
Discount Schedule
(c) 2009 Schneider Electric All Rights Reserved
Starters Accessories
www.schneider-electric.us
TeSys(R) GV2 Manual Starters and Protectors
Refer to Catalog 2502CT0001
www..com
Table 18.136: GV2 Mounting Accessories
Description Common mounting plate Adapter plate Combination block Application For GV2 plus any 3-pole LC1D09 thru LC1D25 contactor. (supplied with GV1G02 connector) For screw mounting of GV2M Interconnect for GV2 plus any 3-pole LC1K or LP1K contactor Interconnect GV2 and LC1D09 thru D32 Interconnect GV2 and LC1D09 thru D32 mounted on LAD31 To allow mounting of GV2M and GV2P on a common bus bar For mounting GV2ME or GV2P and contactor LC1D09 thru D32 Standard Catalog Number Pack b 1 10 10 10 10 10 10 10 GK2AF01 GV2AF02 GV2AF01 GV2AF3 GV2AF4 GV1F03 LAD31 LAD311 $ Price Each 21.60 7.10 14.0 3.20 3.20 5.40 6.20 12.30
GV2GH7
7.5 mm compensation plate Mounting plate
Table 18.137: GV2 Cabling Accessories--Bus Bars
Description Application For feeding 2 GV2 starters For feeding 3 GV2 starters For feeding 4 GV2 starters For feeding 5 GV2 starters Pitch 45 54 72 45 54 45 54 72 54 Standard Pack b 1 1 1 1 1 1 1 1 1 Catalog Number GV2G245 GV2G254 GV2G272 GV2G345 GV2G354 GV2G445 GV2G454 GV2G472 GV2G554 $ Price Each 23.30 23.30 23.30 28.70 28.70 34.20 34.20 34.20 34.20
3-Pole, 63 A Bus Bar
Table 18.138: GV2 Other Cabling Accessories
Description Terminal blocks
1 5 10 1 10
GV2G05 GV1G10 GV1G02 GV2AK1 GV2GH7
34.20 3.60 14.30 16.20 15.00
LAD31
Protective end cover 3-pole flexible connector Conduit adapter (1 2" NPT) Incoming line insulator For GV2P when used in UL 508 Type E applicationsa a Cannot be used with front-mounted auxiliary contact block.
Table 18.139: GV2 Other Accessories
Description Visible isolation block - GV2P Current limiter - GV2M Through-Door operator - GV2P Application Front mount, 3-pole visible isolation on incoming side of GV2P Increases interrupt capacity when attached to GV2M For operating GV2P through enclosure door (red handle, yellow legend plate) For NEMA 1 use. IP54 Standard Pack b Catalog Number 1 GV2AK00 1 GV1L3 1 GV2AP02 $ Price Each 71.40 117.00 135.00
Table 18.140: GV2 Enclosures
Description Mounting Surface mount Enclosures for GV2M with or without accessories (maximum of 1 accessory Flush mount on right and left) Enclosures are not UL or CSA listed. Flush mount reduced width (max. of 1 accessory on right) Rating NEMA 1, IP41 IP55 NEMA 1, IP41 IP55 NEMA 1, IP41 IP55 Catalog Number GV2MC01 GV2MC02 GV2MP01 GV2MP02 GV2MP03 GV2MP04 $ Price Each 54.00 78.00 31.10 54.00 27.90 49.70
Table 18.141: GV2 Enclosures Accessories
Description Padlocking device for GV2M (when padlocked, starter is automatically in Off position) Spring return Mushroom head stop push button (40 mm, red) c Latching Type Standard Packb Catalog Number 1 1 1 1 1 10 10 10 10 10 10 10 10 10 10 10 10 10 GV2V01 GV2K011 GV2K021 GV2K031 GV2K04 GV2E01 GV2SN13 GV2SN14 GV2SN15 GV2SN17 GV2SN23 GV2SN24 GV2SN25 GV2SN27 GV2SN33 GV2SN34 GV2SN35 GV2SN37 $ Price Each 26.90 35.90 104.00 52.00 117.00 18.00
LAD311
Key release (Ronis key no. 455) Turn to Release Latching / Padlockable Turn to Release Sealing kit For enclosures GV2MC01 and GV2MP01 110 V Green 110 V Red 110 V Orange 110 V White 220/240 V Green 220/240 V Red Pilot Light (neon) 220/240 V Orange 220/240 V White 380/440 V Green 380/440 V Red 380/440 V Orange 380/440 V White b Orders must specify multiples of quantities listed. c Supplied with IP55 sealing kit.
26.90
GV2AF3 / GV2AF4
(c) 2009 Schneider Electric All Rights Reserved
I11
Discount Schedule
18-37
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
18
IEC CONTACTORS AND STARTERS
Application Top feed for use with bus bars Bottom feed, to be used with bus bars; can be fitted with GV1L3 current limiter To cover unused bus bar outlets For connecting a GV2 to an LC1D09 thru D25 contactor
Standard Pack b Catalog Number 1 GV1G09
$ Price Each 34.20
Dimensions
TeSys(R) Manual Starters and Protectors
Refer to Catalog 2520CT0001
www..com www.schneider-electric.us
GV2M
GV2AD, AM, AN, AU, AS, AX
Block GV2AD, AM, AN Block GV2AU, AS, AX = 45 1.77
GV2AE
15 .59
Mounting of GV2M
On 35 mm rail C = 78.5 mm (3.09") on AM1DP200 (35 x 7.5 mm) C = 86 mm (3.39") on AM1DE200, ED200 (35 x 15 mm)
89 3.5
10 .39
11 .43
16 44 .63 1.73 66 2.60
9.3 .37
9.3 .37 81 3.19
18 .71 c
GV2P
GV2AD, AM, AN, AU, AS, AX
Block GV2AD, AM, AN Block GV2AU, AS, AX 14 .55 98 3.86
GV2AK00
Mounting of GV2P
On 35 mm rail C = 98.5 mm (3.88") on AM1DP200 (35 x 7.5 mm) C = 106 mm (4.17") on AM1DE200, ED200 (35 x 15 mm) 44.5 1.75
=
89 3.50
=
45 1.77 61 2.40
32 1.26
44.5 1.75
44.5 1.75
=
44.5 1.75
15 .59
9.3 .37
9.3 .37 81 3.19
18 .71
44.5 1.75
c
44.5 1.75
26 1.02
50 1.97 82 3.23
44.5 1.75
13.5 .53
Combination GV2ME + TeSys D range contactor
GV2AF4 + LAD31 Combination GV2P + TeSys D range contactor
GV2P + GV2GH7 for UL 508 Type E application
GV2P + GV2GH7 + TeSys D contactor for UL 508 Type E application
103 4.07
b
c1 c d1 d
45 1.77
191 7.50
b
c1 c
45 1.77
44 1.73
3.6 (91.4) 3.6 (91.4) 3.8 (96.52) 3.8 (96.52)
GV2ME + b c1 c d1 d
LC2D09 to D18 7.4 (188.6) 3.6 (92.7) 3.9 (98.2) 3.9 (98.3) 4.1 (103.8) Surface mounting enclosure GV2MC0* a
2xO5.3x6.3
LC2D25 and D32 7.8 (199) 3.9 (99) 4.11 (104.5) 3.9 (98.3) 1.4 (103.8)
GV2P + b c1 c -- --
LC2D09 to D18 6.61 (168.1) 4.6 (116.8) 4.8 (122.3) -- --
LC2D25 and D32 7.9 (199.5) 4.6 (116.8) 4.8 (122.3) -- --
Flush mounting enclosure GV2MP0* (bracket cut-out)
=
=
b1
147 5.79
130 5.12
84 3.31
93 3.66
=
=
13 0.51
1...6 /0.04...0.24 84 3.31
=
93.5 3.68 106.5 4.19
=
b
71 2.8 92.8 3.65
6.5 0.25
a
4 knock-outs for 16 mm plastic cable glands or no. 16 conduit.
=
GV2 MP01, MP02 MP03, MP04
b IN 5.51 5.24 mm 140 133 IN 5.00 4.61
b1 mm 127 117
18-52
=
(c) 2009 Schneider Electric All Rights Reserved
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
84 3.31
18
IEC CONTACTORS AND STARTERS
Dimensions
www.schneider-electric.us
TeSys(R) Manual Starters and Protectors
Refer to Catalog 2520CT0001
www..com
GV2M with GK2AF01 and LC1K
GV2M with GV2AF01 and LC1K
GV2M with GV2AF01 and LC2K dimensions in mm
Adapter plate GK2AF01
35 1.38
152 6.0
152 6.0
135 5.31
55 2.17
O5.5 .22 45 1.77
35 1.38 105 5 4.13 .2
45 1.77
79 3.11
45 1.77
90 3.54
24 .94
9.5 .37
54 2.13
7.5 mm height compensation plate GV1F03
Mounting external operator GV2AP0*
Door cut-out
GV2M on panel with GV2AF02 adapter plate
7 .276
4xO3.5 O43 0.14 1.7
= 54 2.13
4.2 .17
50/60 1.97/2.36
65 2.56
=
39 1.54
5 .2
53 2.1
1.5...5/0.06...0.20 min.=150 max.=290 5.91 11.42
= 5.2 0.21 ==
= 54 2.13
80 3.15
35 1.38
13 0.51
35 1.38
Sets of bus bars, GV2G445, GV2G454, GV2G472 with terminal block GV2G05
Sets of bus bars with terminal block GV1G09
Sets of bus bars GV2G245, GV2G254, GV2G272
2.5 63
1.2 30
.12 3
.71 18
l
p
l
1.8 45
I 7.0" (179 mm) 8.1" (206 mm) 10.2" (260 mm) P 1.8" (45 mm) 2.1" (54 mm) 2.8" (72 mm) GV3 P Dimensions Mounting on rail AM1 DE200 or AM1 ED201 I 3.5" (89 mm) 3.9" (98 mm) 4.6" (116 mm) 6.0" (152 mm)
GV2G445 GV2G454 GV2G472
0.16 x 1.8" (4 x 45 mm) 0.16 x 2.1" (4 x 54 mm) 0.16 x 1.8" (4 x 45 mm)
GV2G245 GV2G254 GV2G272 GV2G354
0.08 x 1.8" (2 x 45 mm) 0.08 x 2.1" (2 x 54 mm) 0.08 x 2.8"(2 x 72 mm) 0.12 x 2.1" (3 x 54 mm)
(1)
X1
(2)
68
132
64
X1
136
55
144
9
18
X1 = Electrical clearance (ISC max) 40 mm for Ue < 500 V, 50 mm for Ue < 690 V Mounting on panel, using M4 screws
Blocks GV ANpp , GV ADpp , GV AM11 Block GV3 AUpp and GV3 ASpp Mounting on pre-slotted mounting plate AM1 PA
64
68
183
AF1 EA4
137,5
3xO4
136
37,5
136
18,7 18,7
Note: Leave a space of 9 mm between 2 manual motor protectors: either an empty space or side-mounting add-on contact blocks. Horizontal mounting is possible: please consult your regional sales office.
(c) 2009 Schneider Electric All Rights Reserved
137,5
16
18-53
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
18
IEC CONTACTORS AND STARTERS


▲Up To Search▲   

 
Price & Availability of GV2ME01

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X